Level Measurement

Split Type Liquid Level Transmitter

Features

■ With current limiting protection and reverse polarity protection
■Select integrated digital signal processing circuit
■ Split structure design, adjustable zero and full scale output
■ High anti-interference, stable and reliable overall performance

  • GML Series Input Level Transmitter

  • Model

    GML201-B

  • Range

    1、2、5、10、20、50、100、200mH2O

  • Overload

    2 times full scale pressure

  • Precision

    ±0.1%FS;±0.25%FS;±0.5%FS

  • Output signal

    4~20mA;1V~5V;HART;RS-485

  • Load Resistance

    ≤ (U-11) / 0.02 (current type); ≥ 10 (voltage type)

  • Power supply

    11~30VDC

  • Insulation resistance

    500MΩ@500V DC

  • Shell material

    SS304

  • Sensor material

    SS316

  • Seal ring

    Fluororubber

  • Cable

    Φ7.5mm polyethylene special cable

  • Protection level

    IP67 (wiring housing) + IP68 (measuring part)

  • Media suitability

    Various media that are non-corrosive to 316 stainless steel and fluororubber

  • Compensation temperature

    -10℃~+80℃

  • Operating temperature

    -20℃~+70℃

  • Storage temperature

    -30℃~+70℃

  • Temperature Coefficient

    Zero temperature coefficient: 0.03% FS / ° C (≤ 100kPa); 0.02% FS / ° C (> 100kPa)

    Full temperature coefficient: 0.03% FS / ° C (≤ 100kPa); 0.02% FS / ° C (> 100kPa)

  • Long-term stability

    ±0.2%FS/year (maximum)

  • Remarks

    Installation methods, materials, output signals, accuracy requirements, temperature range and other parameters can be customized according to different customer needs.