CN
 

Integrity, truth-seeking and innovation   ──────

Flow Measurement

Pipe Type Thermal Gas Mass Flowmeter

Features

■Applicable to any shape pipe with multiple pipe diameters and known cross-sectional area
■Large range ratio, wide measuring flow rate range
■No moving parts, no pressure loss
■Measure gas mass flow without temperature and pressure compensation
■Efficient power supply design, the whole machine consumes very low power
■Wide supply voltage input

  • GMF901 Series Thermal Gas Mass Flowmeter

  • Model

    GMF901-B

  • Medium

    For any component and mixing ratio known and constant gas, standard gas list, please refer to the ordering information.

  • Accuracy Level

    ±(1.5%RD+0.5%FS)

  • Repeatability

    ±0.5%

  • Responding Speed

    1s

  • Pipe Diameter

    Plug-in type: DN25~DN400; pipe type: flange connection

  • Installation Method

    One-piece or split

  • Connection Method

    Ferrule connection / plug-in / flange connection

  • Ambient Temperature

    -40~60℃

  • Medium Temperature

    -40~150℃

  • Medium Pressure

    1.6MPa (plug-in type) 2.5Mpa/4.0MPa/6.3MPa (pipe type / plug-in flange connection)

  • Signal Interface

    4~20mA@HART, RS-485, Bluetooth, Internet of Things

  • Power Supply

    13.5~42VDC;85~264VAC 50/60HZ

  • Protection Level

    IP65

  • Sensor Material

    316

  • Body Material

    304、316、316L